✨ New Arrivals Just Dropped!Explore
HomeStore

Watts LF957RPDA-OSY-CFM-FS 4 - Part of the LF957RPDA Series

Product image 1

Watts LF957RPDA-OSY-CFM-FS 4 - Part of the LF957RPDA Series

This 4 inch lead free reduced pressure detector backflow preventer assembly help stop the reverse flow of liquids due to backpressure or backsiphonage, where potential health hazard exists. Extremely compact and lighter than traditional designs it is approved for horizontal pattern installation. This assembly consists of a stainless steel body with a quick access sleeve, torsion spring check valves, outside stem and yoke resilient seated gate valves, test cocks, corrosive resistant bottom mounted pressure relief valve, and comes furnished with a cubic per minute meter to detect underground leaks and unauthorized water use. This backflow assembly contains a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When activated through an add-on sensor connection kit, the flood sensor relays a signal that triggers notification of potential flooding to service personnel. The add-on sensor connection kit is available for building management systems and cellular communication.

Features
  • Features a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve
  • Alert features available with add-on sensor connection kit
  • Stainless steel for corrosion resistance
  • UL and FM outside stem and yoke resilient seated gate valves
  • 150 pound ANSI/AWWA CL D flanged
  • Outside screw and yoke shutoffs
  • Compact construction for smaller enclosures
  • Bottom mounted relief valve reduces clearance requirements when installed against an outside wall
  • Torsion spring check valves provides maximum flow at low pressure drop
Specifications
ArmorTek Technology No
Backflow Preventer Type Reduced Pressure Detector Assembly
Body Finish Stainless Steel
Body Material Stainless Steel
Body Pattern Does Not Apply To Product
Brand Watts
Bypass Yes
Bypass Size 3/4 IN
Cap And Tether No
Disc Material Silicone
EAN 098268503708
Elbow Fitting No
Hazard Protection Level Health Hazard
Hot And Harsh Water No
Hydrant Connection No
Inlet Connection Size 4 IN
Inlet Connection Size-Metric 101.6 MM
Inlet Connection Type Grooved Joint
Inlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Inlet Thread Type Does Not Apply To Product
Lead Free YES
Maximum Temperature-Fahrenheit 110
Maximum Working Pressure-BAR 12.10
Maximum Working Pressure-PSI 175
Meter Type CFM
Minimum Temperature - Celsius 1.00
Minimum Temperature-Fahrenheit 33
Outlet Connection Size 4 IN
Outlet Connection Type Grooved Joint
Outlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Outlet Thread Type Does Not Apply To Product
Part Number F122721
Polymer Coating No
Pressure Operation Continuous
Protection Type Backpressure and Backsiphonage
Seat Material EPDM
Series LF957RPDA
Strainer No
Technologies Flood Detection
Tradename None
  • Specification Sheet - Flood Sensor Connection Kit - Watts
  • Specification Sheet - Flood Sensor Connection Kit - Watts (French)
  • Specification Sheet - Flood Sensor Connection Kit - Watts (Spanish)
  • Specification Sheet - LF957RPDA
  • Specification Sheet - LF957RPDA (French)
  • Specification Sheet - LF957RPDA (Spanish)
UPC - 098268503708
$4,086.23

Original: $11,674.95

-65%
Watts LF957RPDA-OSY-CFM-FS 4 - Part of the LF957RPDA Series

$11,674.95

$4,086.23

Product Information

Shipping & Returns

Description

This 4 inch lead free reduced pressure detector backflow preventer assembly help stop the reverse flow of liquids due to backpressure or backsiphonage, where potential health hazard exists. Extremely compact and lighter than traditional designs it is approved for horizontal pattern installation. This assembly consists of a stainless steel body with a quick access sleeve, torsion spring check valves, outside stem and yoke resilient seated gate valves, test cocks, corrosive resistant bottom mounted pressure relief valve, and comes furnished with a cubic per minute meter to detect underground leaks and unauthorized water use. This backflow assembly contains a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When activated through an add-on sensor connection kit, the flood sensor relays a signal that triggers notification of potential flooding to service personnel. The add-on sensor connection kit is available for building management systems and cellular communication.

Features
  • Features a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve
  • Alert features available with add-on sensor connection kit
  • Stainless steel for corrosion resistance
  • UL and FM outside stem and yoke resilient seated gate valves
  • 150 pound ANSI/AWWA CL D flanged
  • Outside screw and yoke shutoffs
  • Compact construction for smaller enclosures
  • Bottom mounted relief valve reduces clearance requirements when installed against an outside wall
  • Torsion spring check valves provides maximum flow at low pressure drop
Specifications
ArmorTek Technology No
Backflow Preventer Type Reduced Pressure Detector Assembly
Body Finish Stainless Steel
Body Material Stainless Steel
Body Pattern Does Not Apply To Product
Brand Watts
Bypass Yes
Bypass Size 3/4 IN
Cap And Tether No
Disc Material Silicone
EAN 098268503708
Elbow Fitting No
Hazard Protection Level Health Hazard
Hot And Harsh Water No
Hydrant Connection No
Inlet Connection Size 4 IN
Inlet Connection Size-Metric 101.6 MM
Inlet Connection Type Grooved Joint
Inlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Inlet Thread Type Does Not Apply To Product
Lead Free YES
Maximum Temperature-Fahrenheit 110
Maximum Working Pressure-BAR 12.10
Maximum Working Pressure-PSI 175
Meter Type CFM
Minimum Temperature - Celsius 1.00
Minimum Temperature-Fahrenheit 33
Outlet Connection Size 4 IN
Outlet Connection Type Grooved Joint
Outlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Outlet Thread Type Does Not Apply To Product
Part Number F122721
Polymer Coating No
Pressure Operation Continuous
Protection Type Backpressure and Backsiphonage
Seat Material EPDM
Series LF957RPDA
Strainer No
Technologies Flood Detection
Tradename None
  • Specification Sheet - Flood Sensor Connection Kit - Watts
  • Specification Sheet - Flood Sensor Connection Kit - Watts (French)
  • Specification Sheet - Flood Sensor Connection Kit - Watts (Spanish)
  • Specification Sheet - LF957RPDA
  • Specification Sheet - LF957RPDA (French)
  • Specification Sheet - LF957RPDA (Spanish)
UPC - 098268503708