✨ New Arrivals Just Dropped!Explore
HomeStore

Watts LF009M2-QTW/PRESS-FS 2 - Part of the LF009 Series

Product image 1

Watts LF009M2-QTW/PRESS-FS 2 - Part of the LF009 Series

This 2 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards and for contaminants at the service line entrance. This assembly consists of a lead free bronze body, NPT end connections with Viega ProPress® adaptors, quarter turn ball valve shutoffs with tee handles, top mounted test cocks, two in-line independent check valves, captured springs, and replaceable check seats with an internal relief valve for reduced space requirements. This backflow assembly includes flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When activated through an add-on sensor connection kit, the flood sensor can send an alert to notify the user of potential flooding. Add-on sensor connection kits are available for both BMS and cellular communications.

Features
  • Features flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve
  • Alert features available with add-on sensor connection kit
  • Lead free bronze body construction for durability
  • NPT inlet and outlet connections with Viega ProPress® adaptors
  • Quarter turn full port resilient seated ball valve shutoffs
  • Single access cover and modular check construction for the ease of maintenance
  • Internal relief valve for reduced installation clearances
Specifications
ArmorTek Technology No
Backflow Preventer Type Reduced Pressure Zone Assembly
Body Finish Cast Copper Silicon Alloy
Body Material Lead Free Copper Silicon Alloy
Body Pattern Inline
Brand Watts
Buy American Act Compliant YES
Bypass No
Bypass Size Does Not Apply To Product
Cap And Tether No
Disc Material Silicone
EAN 098268350074
Elbow Fitting No
Hazard Protection Level Health Hazard
Hot And Harsh Water No
Hydrant Connection No
Inlet Connection Size 2 IN
Inlet Connection Size-Metric 51 MM
Inlet Connection Type Press
Inlet Shutoff Valve Type Quarter Turn Ball Valve
Inlet Thread Type Does Not Apply To Product
Lead Free YES
Maximum Temperature-Fahrenheit 180
Maximum Working Pressure-BAR 12.10
Maximum Working Pressure-PSI 175
Meter Type No Meter
Minimum Temperature - Celsius 1.00
Minimum Temperature-Fahrenheit 33
Outlet Connection Size 2 IN
Outlet Connection Type Press
Outlet Shutoff Valve Type Quarter Turn Ball Valve
Outlet Thread Type Does Not Apply To Product
Part Number 88004121
Polymer Coating No
Pressure Operation Continuous
Protection Type Backpressure and Backsiphonage
Seat Material Stainless Steel
Series LF009
Strainer No
Technologies Flood Detection
Tradename None
  • Field Guide - Backflow Preventer Repair Parts 007 and 009
  • Specification Sheet - Flood Sensor Connection Kit - Watts
  • Specification Sheet - Flood Sensor Connection Kit - Watts (French)
  • Specification Sheet - Flood Sensor Connection Kit - Watts (Spanish)
  • Specification Sheet - LF009
  • Specification Sheet - LF009 (French)
  • Specification Sheet - LF009 (Spanish)
UPC - 098268350074
$1,146.60

Original: $3,276.00

-65%
Watts LF009M2-QTW/PRESS-FS 2 - Part of the LF009 Series

$3,276.00

$1,146.60

Product Information

Shipping & Returns

Description

This 2 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards and for contaminants at the service line entrance. This assembly consists of a lead free bronze body, NPT end connections with Viega ProPress® adaptors, quarter turn ball valve shutoffs with tee handles, top mounted test cocks, two in-line independent check valves, captured springs, and replaceable check seats with an internal relief valve for reduced space requirements. This backflow assembly includes flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When activated through an add-on sensor connection kit, the flood sensor can send an alert to notify the user of potential flooding. Add-on sensor connection kits are available for both BMS and cellular communications.

Features
  • Features flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve
  • Alert features available with add-on sensor connection kit
  • Lead free bronze body construction for durability
  • NPT inlet and outlet connections with Viega ProPress® adaptors
  • Quarter turn full port resilient seated ball valve shutoffs
  • Single access cover and modular check construction for the ease of maintenance
  • Internal relief valve for reduced installation clearances
Specifications
ArmorTek Technology No
Backflow Preventer Type Reduced Pressure Zone Assembly
Body Finish Cast Copper Silicon Alloy
Body Material Lead Free Copper Silicon Alloy
Body Pattern Inline
Brand Watts
Buy American Act Compliant YES
Bypass No
Bypass Size Does Not Apply To Product
Cap And Tether No
Disc Material Silicone
EAN 098268350074
Elbow Fitting No
Hazard Protection Level Health Hazard
Hot And Harsh Water No
Hydrant Connection No
Inlet Connection Size 2 IN
Inlet Connection Size-Metric 51 MM
Inlet Connection Type Press
Inlet Shutoff Valve Type Quarter Turn Ball Valve
Inlet Thread Type Does Not Apply To Product
Lead Free YES
Maximum Temperature-Fahrenheit 180
Maximum Working Pressure-BAR 12.10
Maximum Working Pressure-PSI 175
Meter Type No Meter
Minimum Temperature - Celsius 1.00
Minimum Temperature-Fahrenheit 33
Outlet Connection Size 2 IN
Outlet Connection Type Press
Outlet Shutoff Valve Type Quarter Turn Ball Valve
Outlet Thread Type Does Not Apply To Product
Part Number 88004121
Polymer Coating No
Pressure Operation Continuous
Protection Type Backpressure and Backsiphonage
Seat Material Stainless Steel
Series LF009
Strainer No
Technologies Flood Detection
Tradename None
  • Field Guide - Backflow Preventer Repair Parts 007 and 009
  • Specification Sheet - Flood Sensor Connection Kit - Watts
  • Specification Sheet - Flood Sensor Connection Kit - Watts (French)
  • Specification Sheet - Flood Sensor Connection Kit - Watts (Spanish)
  • Specification Sheet - LF009
  • Specification Sheet - LF009 (French)
  • Specification Sheet - LF009 (Spanish)
UPC - 098268350074