✨ New Arrivals Just Dropped!Explore
HomeStore

Watts 007M1DCDA-OSY-GPM-FZ 2 - Part of the 007M1DCDA Series

Product image 1

Watts 007M1DCDA-OSY-GPM-FZ 2 - Part of the 007M1DCDA Series

This 2 inch double check detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection at cross-connections identified as non-health hazards such as on fire protection systems and from other contaminants found at the service line entrance. This compact modular design with a single access cover for easy maintenance is approved for horizontal and vertical flow up installation. It consists of a cast bronze body, outside stem and yoke resilient seated gate valves, captured spring check valves, and four test cocks. It comes with a gallon per minute meter to detect underground leaks and unauthorized water use. The double check valve includes a freeze sensor for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point. Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), irrigation management systems (IMS).

Features
  • Includes a freeze sensor for use with SentryPlus Alert technology to signal facility personnel when temperature nears and reaches the freezing point
  • Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures
  • Cast bronze body construction
  • Furnished with a gallon per minute meter
  • Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS)
  • Replaceable seats and discs
  • No special tools are required for servicing
Specifications
ArmorTek Technology No
Backflow Preventer Type Double Check Detector Assembly
Body Finish Cast Bronze
Body Material Cast Bronze
Body Pattern Inline
Brand Watts
Bypass Yes
Bypass Size 1/2 IN
Cap And Tether No
Disc Material Silicone
EAN 098268593785
Elbow Fitting No
Hazard Protection Level Non Health Hazard
Hot And Harsh Water No
Hydrant Connection No
Inlet Connection Size 2 IN
Inlet Connection Size-Metric 50 MM
Inlet Connection Type Grooved Joint
Inlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Inlet Thread Type Does Not Apply To Product
Lead Free NO
Maximum Temperature-Fahrenheit 110
Maximum Working Pressure-BAR 12.10
Maximum Working Pressure-PSI 175
Meter Type GPM
Minimum Temperature - Celsius 0.50
Minimum Temperature-Fahrenheit 33
Outlet Connection Size 2 IN
Outlet Connection Type Female Threaded
Outlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Outlet Thread Type Does Not Apply To Product
Part Number T062726
Polymer Coating No
Pressure Operation Continuous
Protection Type Backpressure and Backsiphonage
Seat Material Rubber
Series 007M1DCDA
Strainer No
Technologies Freeze Detection
Tradename None
  • Specification Sheet - 007M1DCDA
  • Specification Sheet - 007M1DCDA (French)
  • Specification Sheet - 007M1DCDA (Spanish)
  • Specification Sheet - Freeze Sensor Connection Kit
  • Specification Sheet - Freeze Sensor Connection Kit (French)
  • Specification Sheet - Freeze Sensor Connection Kit (Spanish)
UPC - 098268593785
$4,095.42

Original: $11,701.20

-65%
Watts 007M1DCDA-OSY-GPM-FZ 2 - Part of the 007M1DCDA Series

$11,701.20

$4,095.42

Product Information

Shipping & Returns

Description

This 2 inch double check detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection at cross-connections identified as non-health hazards such as on fire protection systems and from other contaminants found at the service line entrance. This compact modular design with a single access cover for easy maintenance is approved for horizontal and vertical flow up installation. It consists of a cast bronze body, outside stem and yoke resilient seated gate valves, captured spring check valves, and four test cocks. It comes with a gallon per minute meter to detect underground leaks and unauthorized water use. The double check valve includes a freeze sensor for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point. Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), irrigation management systems (IMS).

Features
  • Includes a freeze sensor for use with SentryPlus Alert technology to signal facility personnel when temperature nears and reaches the freezing point
  • Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures
  • Cast bronze body construction
  • Furnished with a gallon per minute meter
  • Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS)
  • Replaceable seats and discs
  • No special tools are required for servicing
Specifications
ArmorTek Technology No
Backflow Preventer Type Double Check Detector Assembly
Body Finish Cast Bronze
Body Material Cast Bronze
Body Pattern Inline
Brand Watts
Bypass Yes
Bypass Size 1/2 IN
Cap And Tether No
Disc Material Silicone
EAN 098268593785
Elbow Fitting No
Hazard Protection Level Non Health Hazard
Hot And Harsh Water No
Hydrant Connection No
Inlet Connection Size 2 IN
Inlet Connection Size-Metric 50 MM
Inlet Connection Type Grooved Joint
Inlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Inlet Thread Type Does Not Apply To Product
Lead Free NO
Maximum Temperature-Fahrenheit 110
Maximum Working Pressure-BAR 12.10
Maximum Working Pressure-PSI 175
Meter Type GPM
Minimum Temperature - Celsius 0.50
Minimum Temperature-Fahrenheit 33
Outlet Connection Size 2 IN
Outlet Connection Type Female Threaded
Outlet Shutoff Valve Type Outside Stem And Yoke Gate Valve
Outlet Thread Type Does Not Apply To Product
Part Number T062726
Polymer Coating No
Pressure Operation Continuous
Protection Type Backpressure and Backsiphonage
Seat Material Rubber
Series 007M1DCDA
Strainer No
Technologies Freeze Detection
Tradename None
  • Specification Sheet - 007M1DCDA
  • Specification Sheet - 007M1DCDA (French)
  • Specification Sheet - 007M1DCDA (Spanish)
  • Specification Sheet - Freeze Sensor Connection Kit
  • Specification Sheet - Freeze Sensor Connection Kit (French)
  • Specification Sheet - Freeze Sensor Connection Kit (Spanish)
UPC - 098268593785